Fido System Software:
System Requirements
PC: Intel-Compatible PC or Mac running
Windows XP, Vista, Windows 7
RAM: 128 MB min., 256 MB recommended
Disk Space: 20 MB free
Communications: 1 free RS-232 or USB port
Current Measurement
Average Error:
< ±0.50%, ±10 mA
Max Error:
< ±2.50%, ±100 mA
Voltage Measurement
Average Error: < ±0.01%,
±10 mV AC
Max Error: < ±0.10%, ±100 mV AC
Measurement Ratings (per Breaker Monitor)
Circuits, Current, Voltage
16 single-pole, or 50 Amps Max, 105-130 VAC
up to 8 dual-pole 50 Amps Max, 210-240 VAC
Breaker Monitor
Dimensions: 8.5” H x 6.3” D x 4.3” D
Weight: 1.6 lbs
Environmental
Operating Temp: -40°C to +85°C
Storage Temp: -55°C to +125°C
Power Line Carrier Communications
Emissions: Designed to be compliant with FCC,
Industry Canada, Japan MPT and
CENELEC EN50065-1 specification for
low-voltage signaling
Bit Rate: 5.4kbps raw bit rate
Communication: Dual Frequency BPSK with DSP-enhanced receiver
Carrier Frequencies: 132 kHz primary, 115 KHz secondary
(CENELEC C-Band)
Enclosure Type: 3R – Rainproof
Max Ratings: 240 VAC, 60 A
Meter Interface: Compatible with all standard utility
meters: smart or legacy
Fido Network Adapter:
Input Power
Voltage: 105-130 VAC
Current: < 0.5 mW Typical,
1.5 mW Max
Connection: IEC320 inlet;
6’ line cord with NEMA
standard 5-15P plug
Dimensions: 6” H x 2.8” D x 2.2” D
Weight: 1.1 lbs